Customization: | Available |
---|---|
After-sales Service: | Support |
Warranty: | 6 Years |
Still deciding? Get samples of US$ 375/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type designation
|
SG110CX
|
||
Efficiency
|
|||
Max. efficiency
|
98.7%
|
||
European efficiency
|
98.5%
|
||
Input (DC)
|
|||
Max. PV input voltage
|
1100 V *
|
||
Min. PV input voltage / Start-up input voltage
|
200V/ 250V
|
||
Rated input voltage
|
585V
|
||
MPP voltage range
|
200V-1000V
|
||
MPP voltage range for nominal power
|
550V-850V
|
||
No. of independent MPP inputs
|
9
|
||
No. of PV strings per MPPT
|
2
|
||
Max. PV input current
|
26 A*9
|
||
Max. DC short-circuit current
|
40 A*9
|
||
Output (AC)
|
|||
Rated AC output power
|
110 kVA @ 45 ºC / 100 kVA @ 50 ºC
|
||
Max. AC output current
|
158.8A
|
||
Rated AC voltage
|
3 / N / PE, 230 / 400 V
|
||
AC voltage range
|
320-460V
|
||
Rated grid frequency
|
50Hz / 60Hz
|
||
Nominal grid frequency / Grid frequency range
|
50 Hz / 45 - 55 Hz, 60 Hz / 55 - 65 Hz
|
||
Harmonic (THD)
|
<3 % (at rated power)
|
||
Power factor at Rated power / Adjustable power factor
|
>0.99/0.8 leading - 0.8 laggin
|
||
DC current injection
|
< 0.5 % In
|
||
Feed-in phases / AC connection phases
|
3/3
|
||
General Data
|
|||
Dimensions(
W*H*D) |
1051*660*362.5 mm
|
||
Weight
|
89kg
|
||
Topology
|
Transformerless
|
||
Degree of protection
|
IP66
|
||
Night power consumption
|
<2W
|
||
Operating ambient temperature range
|
-30 ºC to 60 ºC
|
||
Allowable relative humidity range (non-condensing
|
0% - 100%
|
||
Cooling method
|
Smart forced air cooling
|
||
Max. operating altitude
|
4000m
|
||
Display
|
LED, Bluetooth+APP
|
||
Communication
|
RS485 / Optional: Wi-Fi, Ethernet
|
||
DC connection type
|
MC4 (Max. 6 mm² )
|
||
AC connection type
|
OT / DT terminal (Max. 240 mm²)
|
||
Grid Compliance
|
IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N 4110:2018, VDE-AR-N 4120:2018, IEC 61000-6-3, EN 50549, AS/NZS 4777.2:2015, CEI 0-21, VDE 0126-1-1/A1 VFR 2014, UTE C15-712-1:2013, DEWA
|
||
Grid Support
|
Q at night function, LVRT, HVRT,active & reactive power control and power ramp rate control
|
||
Protection&Function
|
|||
Grid monitoring
|
Yes
|
||
DC reverse connection protection
|
Yes
|
||
AC short-circuit protection
|
Yes
|
||
Leakage current protection
|
Yes
|
||
Ground fault monitoring
|
Yes
|
||
DC switch
|
Yes (not available for Australia)
|
||
AC switch
|
No
|
||
PV String current monitoring
|
Yes
|
||
PID recovery function
|
Yes
|
||
Overvoltage protection
|
DC Type II / AC Type II
|